Unconstrained Measurement of Heart Rate Considering Harmonics of Respiratory Signal Using Flexible Tactile Sensor Sheet

Kazuya Matsuo*, Toshiharu Mukai**, and Shijie Guo***

*Faculty of Engineering, Kyushu Institute of Technology
1-1 Sensui, Tobata, Kitakyushu, Fukuoka 804-8550, Japan

**Meijo University
1-501 Shiogamaguchi, Tempaku, Nagoya, Aichi 468-8502, Japan

***Hebei University of Technology
Xiping Road No. 5340, Beichen District, Tianjin 300130, China

Received:
January 20, 2021
Accepted:
April 28, 2021
Published:
August 20, 2021
Keywords:
harmonics of a respiratory signal, heart rate measurement, unconstrained measurement, tactile
Abstract

Measurement of the sleeping state is useful for monitoring the health of a person being nursed. The sleeping state can be estimated from biological information such as respiration rate, heart rate, body motion, and lying posture. A heart rate measurement method that considers the harmonics of a respiratory signal is described herein. The harmonics of respiratory signals for heart rate measurement has not been considered hitherto. An unconstrained method is proposed for measuring respiration, heart rate, and lying posture using a Smart Rubber sensor, which is a rubber-based flexible planar tactile sensor developed for this study. Respiration and heart rates are measured by applying frequency analysis to time-series data of body pressure. The harmonics of a respiratory signal serves as noise in heart rate measurement. Therefore, the heart rate measurement is improved by eliminating the effects of harmonics. The average frequency error of the heart rate measurement by our proposed method is 0.144 Hz. Experimental results show that our proposed method enhances the precision of heart rate measurement. Hence, this method enables the accurate measurement of the sleeping state.

Heartbeat by eliminating respiratory harmonics

Heartbeat by eliminating respiratory harmonics

Cite this article as:
K. Matsuo, T. Mukai, and S. Guo, “Unconstrained Measurement of Heart Rate Considering Harmonics of Respiratory Signal Using Flexible Tactile Sensor Sheet,” J. Robot. Mechatron., Vol.33 No.4, pp. 826-832, 2021.
Data files:
References
  1. [1] T. Mukai, S. Hirano, H. Nakashima, Y. Sakaida, and S. Guo, “Realization and Safety Measures of Patient Transfer by Nursing-Care Assistant Robot RIBA with Tactile Sensors,” J. Robot. Mechatron., Vol.23, No.3, pp. 360-369, doi: 10.20965/jrm.2011.p0360, 2011.
  2. [2] C. A. Kushida, M. R. Littner, T. Morgenthaler, C. A. Alessi, D. Bailey, J. Coleman Jr., L. Friedman, M. Hirshkowitz, S. Kapen, M. Kramer, T. Lee-Chiong, D. L. Loube, J. Owens, J. P. Pancer, and M. Wise, “Practice parameters for the indications for polysomnography and related procedures: An update for 2005,” J. of Sleep, Vol.28, No.4, pp. 499-521, 2005.
  3. [3] A. Rechtschaffen and A. Kales, “A Manual of Standardized Terminology, Techniques and Scoring System for Sleep Stages of Human Subjects,” Bethesda, MD: U.S. Dept. of Health, Education, and Welfare, Public Health Services-National Institutes of Health, National Institute of Neurological Diseases and Blindness, Neurological Information Network, 1968.
  4. [4] T. Watanabe and K. Watanabe, “Estimation of the Sleep Stages by the Non-restrictive Air Mattress Sensor: Relation between the Change in the Heart Rate and Sleep Stages,” Trans. of the Society of Instrument and Control Engineers, Vol.37, No.9, pp. 821-828, 2001.
  5. [5] Y. Kurihara and K. Watanabe, “Sleep-Stage Decision Algorithm by Using Heartbeat and Body-Movement Signals,” IEEE Trans. on Systems, Man, and Cybernetics, Part A, Vol.42, No.6, pp. 1450-1459, 2012.
  6. [6] T. Watanabe and K. Watanabe, “Noncontact Method for Sleep Stage Estimation,” IEEE Trans. on Biomedical Engineering, Vol.51, No.10, pp. 1735-1748, 2004.
  7. [7] Y. Matsuura, H. Jeong, K. Yamada, K. Watabe, K. Yoshimoto, and Y. Ohno, “Screening Sleep Disordered Breathing with Noncontact Measurement in a Clinical Site,” J. Robot. Mechatron., Vol.29, No.2, pp. 327-337, doi: 10.20965/jrm.2017.p0327, 2017.
  8. [8] Y. Kambayashi and H. Hagiwara, “Estimating Sleep Cycle Using Body Movement Density,” Proc. of the 2012 5th Int. Conf. on Biomedical Engineering and Informatics, pp. 1029-1033, 2012.
  9. [9] S. Okada, Y. Ohno, Goyahan, K. Kato-Nishimura, I. Mohri, and M. Taniike, “Examination of Non-restrictive and Non-invasive Sleep Evaluation Technique for Children Using Difference Images,” Proc. of the 30th Annual Int. Conf. of the IEEE Engineering in Medicine and Biology Society, pp. 2483-2487, 2008.
  10. [10] T. Mikami, Y. Kojima, K. Yonezawa, M. Yamamoto, and M. Furukawa, “Spectral Classification of Oral and Nasal Snoring Sounds Using a Support Vector Machine,” J. Adv. Comput. Intell. Intell. Inform., Vol.17, No.4, pp. 611-621, doi: 10.20965/jaciii.2013.p0611, 2013.
  11. [11] W. Wen, J. Zeng, G. Hu, and G. Liu, “A System for the Comprehensive Quantification of Real-Time Heartbeat Activity,” J. Adv. Comput. Intell. Intell. Inform., Vol.20, No.5, pp. 765-772, doi: 10.20965/jaciii.2016.p0765, 2016.
  12. [12] A. Deguchi and H. Hagiwara, “Evaluation of Heart Rate Variability and Respiratory Variability during Sleep Using a Lorenz Plot,” J. of Sleep and Biological Rhythms, Vol.9, No.4, 366, 2011.
  13. [13] R. M. Harper, V. L. Schechtman, and K. A. Kluge, “Machine Classification of Infant Sleep State Using Cardiorespiratory Measures,” Electroencephalography and Clinical Neurophysiology, Vol.67, No.4, pp. 379-387, 1987.
  14. [14] T. Mukai, K. Matsuo, Y. Kato, A. Shimizu, and S. Guo, “Lying Posture Detection for Unconstrained Measurement of Respiration and Heartbeat of a Person on a Bed,” Proc. of the 11th IASTED Int. Conf. on Biomedical Engineering, pp. 46-53, doi: 10.2316/P.2014.818-014, 2014.
  15. [15] K. Matsuo, T. Mukai, Y. Kato, A. Shimizu, and S. Guo, “Measurement of Respiration and Heartbeat Using a Flexible Tactile Sensor Sheet on a Bed,” Proc. of the 11th IASTED Int. Conf. on Biomedical Engineering, pp. 59-64, doi: 10.2316/P.2014.818-031, 2014.
  16. [16] J. W. Cooley and J. W. Tukey, “An Algorithm for the Machine Calculation of Complex Fourier Series,” Mathematics of Computation, Vol.19, No.90, pp. 297-301, 1965.
  17. [17] C. F. Gauss, “Nachlass: Theoria Interpolationis Methodo Nova Tractata,” Carl Friedrich Gauss Werke, Band 3, Koniglichen Gesellschaft der Wissenschaften, Gottingen, pp. 265-327, 1866.
  18. [18] S. Guo, Y. Kato, H. Ito, and T. Mukai, “Development of Rubber-Based Flexible Sensor Sheet for Care-Related Apparatus,” Sumitomo Electric Industries Technical Review, No.75, pp. 125-131, 2012.
  19. [19] R. Cork, “XSENSOR Technology: a Pressure Imaging Overview,” Sensor Review, Vol.27, No.1, pp. 24-28, 2007.

*This site is desgined based on HTML5 and CSS3 for modern browsers, e.g. Chrome, Firefox, Safari, Edge, Opera.

Last updated on Apr. 18, 2024