Human Joint Motion Recognition Using Ultrasound Pulse Echo Based on Test Feature Classifier

Yoichiro Tsutsui*, Takayuki Tanaka**, Shun'ichi Kaneko**, Yukinobu Sakata***, and Maria Q. Feng****

*Morita Corporation, 5-5-20 Shoji-Higashi, Ikuno-ku, Osaka 544-0003, Japan

**Hokkaido University, Kita 14 Nishi 9, Kita-ku, Sapporo, Japan

***Toshiba Corporation, 1, Komukai-Tpshiba-cho, Saiwai-ku, Kawasaki, Kanagawa 212-8582, Japan

****University of California, Irvine, Irvine, CA, USA

Received:
May 18, 2009
Accepted:
August 20, 2009
Published:
October 20, 2009
Keywords:
human motion recognition, ultrasound, test feature classifier (TFC)
Abstract
The simultaneous joint torque and angle recognition for dynamic movement we propose using ultrasound echo and is test feature classifier is for application in human-machine systems such as wearable robots. Ultrasound emitted on the skin surface and reflected within the body is used to recognize features extracted from the echo. Features is change based on the muscle movement related to target joint movements enabling joint movement to be recognized. Experiments conducted to recognize elbow movement involved classifying a test data set into torque and angle classes based on feature scores rectified and integrated in 6 blocks extracted from ultrasound echoes. Correct classification was 54% for torque recognition, and 67% for angle recognition. Some data classified incorrectly was still in classes close to the correct class, with quasi correct classification 88% for torque and 94% for angle, corresponding to allowing larger classes for correct classification. Results demonstrated that recognition using our proposal was more successful than random selection at 11% for torque recognition and 13% for anble recognition. A strategy we describe for reducing the number of features to decrease calculation time cost, reduced by 50% while maintaining accuracy.
Cite this article as:
Y. Tsutsui, T. Tanaka, S. Kaneko, Y. Sakata, and M. Feng, “Human Joint Motion Recognition Using Ultrasound Pulse Echo Based on Test Feature Classifier,” J. Robot. Mechatron., Vol.21 No.5, pp. 597-606, 2009.
Data files:
References
  1. [1] Y. Tsutsui, Y. Sakata, T. Tanaka, S. Kaneko, and M. Q. Feng, “Human Joint Movement Recognition by Using Ultrasound Echo Based on Test Feature Classifier,” Proc. of the IEEE SENSORS 2007, pp. 1205-1208 (CDROM), Oct. 2007.
  2. [2] T. Tanaka, R. Yamaguchi, S. Hori, S. Moromugi, and M. Q. Feng, “Ultrasonic Sensor Disk for Detecting Muscular Force,” Proc. of IEEE Int. Workshop on Robot-Human Interaction 2003, pp. 291-295, Nov. 2003.
  3. [3] Y. Tsutsui, T. Tanaka, S. Kaneko, and M. Q. Feng, “Duplex Ultrasonic Muscle Activity Sensor,” Proc. of the IEEE SENSORS 2005, pp. 310-313 (CDROM), Nov. 2005.
  4. [4] Y. Tsutsui, T. Tanaka, S. Kaneko, and M. Q. Feng, “Joint torque and Angle Estimation by Using Ultrasound Transmitted through Human Muscle,” J. of the Japan Society for Precision Engineering, Vol.73, No.9, pp. 1062-1067, Nov. 2007 (In Japanese).
  5. [5] Y. Tsutsui, K. Hayase, T. Tanaka, S. Kaneko, and M. Q. Feng, “Simultaneous Estimation of torque and Angle of Human Elbow Joint by Using Ultrasound Echo,” J. of the Japan Society for Precision Engineering, Vol.73, No.11, pp. 1273-1278, Nov. 2007 (In Japanese).
  6. [6] E. A. Clancy and N. Hogan, “Estimation of Joint Torque from the Surface EMG,” Proc. of the Annual Int. Conf. of the IEEE Engineering in Medicine and Biology Society, Vol.13, No.2, pp. 877-878, Nov. 1991.
  7. [7] O. C. J. Lippold, “The Relation Between Integrated Action Potentials in a Human Muscle and Its Isometric Tension,” J. Physiol., Vol.117, No.4, pp. 492-499, Aug. 1952.
  8. [8] B. Bigland and O.C.J.Lippold, “The Relation between Force, Velocity and Integrated Electrical Activity in Human Muscle,” J. Physiol., Vol.123, No.1, pp. 214-224, 1954.
  9. [9] O. Fukuda, T. Tsuji, M. Kaneko, and A. Otsuka, “A Human-Assisting Manipulator Teleoperated by EMG signals and Arm Motions,” IEEE Trans. on Robotics and Automation, Vol.19, No.2, pp. 210-222, 2003.
  10. [10] K. Kiguchi, S.Kariya, K. Watanabe, and T. Fukuda, “An Exoskeletal Robot for Human Elbow Motion Support -Sensor Fusion, Adaptation, and Control,” IEEE Trans. on Systems, Man and Cybernetics, Vol.B 31, No.3, pp. 353-361, Jun. 2001.
  11. [11] K. Akataki, K. Mita, M. Watakabe, and K. Itoh, “Mechanomyogram and force relationship during voluntary isometric ramp contractions of the biceps brachii muscle,” Eur. J. Appl. Physiol., Vol.84, No.1-2, pp. 19-25, 2001.
  12. [12] S. Moromugi, Y. Koujina, S. Ariki, A. Okamoto, T. Tanaka, M. Q. Feng, and T. Ishimatsu, “Muscle Stiffness Sensor to Control Assisting Device for Disabled,” Proc. of The Eighth Int. Symp. on Artificial Life and Robotics (AROB8th '03), pp. 459-462, Jan. 2003.
  13. [13] Y. Tamura and I. Hatta, “Changes in muscle stiffness during contraction recorded using ultrasonic waves,” Nature, Vol.299, No.14, pp. 631-633, Oct. 1982.