single-dr.php

JDR Vol.4 No.3 pp. 175-181
(2009)
doi: 10.20965/jdr.2009.p0175

Paper:

Current State of Seismic-Isolation Design

Nagahide Kani

The Japan Society of Seismic Isolation, JIA Bldg. 2FL, 2-3-18 Jingumae, Shibuyaku, Tokyo 150-0001, Japan

Received:
March 25, 2009
Accepted:
June 22, 2009
Published:
June 1, 2009
Keywords:
seismic-isolation, safety, functionality, isolator, damper
Abstract
Japan has the world’s highest number of seismic-isolation structures - a figure that has been gradually increasing since the 1995 South Hyogo earthquake that devastated Kobe and its environs. It is the main reason that two seismically isolated buildings in Kobe have shown good performance during and after earthquakes. As the awareness of the benefits of seismic isolation has grown, it is being accepted more among people, to maintain structural safety and functionality during and after earthquakes. Safety, property value, and functionality must be maintained by the earthquake-resistance performance of buildings. This seismic isolation system is the appropriate earthquake-resistant method in consideration of satisfying these three items, and positive in the design of structures, such as residences, hospitals, and high-rise buildings, then in retrofitting. This paper focuses on the current status of seismically isolated structures and problems in seismic isolation design.
Cite this article as:
N. Kani, “Current State of Seismic-Isolation Design,” J. Disaster Res., Vol.4 No.3, pp. 175-181, 2009.
Data files:
References
  1. [1] Editing Committee of MLIT, JSSI, BCJ, “Commentary on TechnicalStandards for Seismically Isolated Buildings and Devices-Notification No2009 and 1446 in 2000,” Kogakutosho Co. Ltd.,Japan, May 2001.
  2. [2] Technology Committee, JSSI, “Time History Analysis Method forSeismically Isolated Buildings,” JSSI, Japan, Nov. 2005.
  3. [3] Technology Committee, JSSI, “Standard for Construction Methodon Seismically Isolated Buildings-2005,” Economic Research Association,Japan, Nov. 2005.
  4. [4] Maintenance and Inspection Committee, JSSI, “Maintenance Standardfor Seismically Isolated Buildings-2007,” JSSI, Japan, Aug.2007.
  5. [5] Technology Committee, JSSI, “Architectural and Building EquipmentsStandard for Seismically Isolated Buildings-2001,” JSSI,Japan, Aug. 2007.
  6. [6] Technology Committee, JSSI, “List of Devices for SI in Japan,”JSSI, Japan, Feb. 2005.
  7. [7] Retrofit Committee, JBDPA & JSSI, “Guidelines for Retrofit withSeismic Isolation and Response Control,” Japan Building DisasterPrevention Association, Japan, Jun. 2006.
  8. [8] NEDO Report, 2007, “Research Project for Seismic Isolation Devicesand Systems, 2006,” Report of Research Project, NEDOCode100009926, 06002383-06002384, Feb. 2004.
  9. [9] Y. Takenaka, et al., “Earthquake observation result of a baseisolatedbuilding in Kushiro city during the Tokachi-oki Earthquakein 2003,” Journal menshin, JSSI No.43, pp. 31-35, Feb. 2004.
  10. [10] T. Kashima, et al., “Strong Motion Records Observed at the Kushiro Government Office Building during the Tokachi-oki Earthquake in2003,” Journal menshin, JSSI No.43, pp. 36-38, Feb. 2004.
  11. [11] M. Tohdo, et al., “Seismic Behavior of Kushiro-shinyou-kumiaiduring the Tokachi-oki Earthquake in 2003,” Journal menshin, JSSINo.43, pp. 39-40, Feb. 2004.
  12. [12] S. Sakai, et al., “Dynamic Behavior of a Base-Isolated Hospital Building in Kushiro City during the Tokachi Offshore Earthquakein 2003,” Journal menshin, JSSI No.43, pp. 41-43, Feb. 2004.
  13. [13] Diffusion Committee Report, “The Survey of Questionnaires to Residents in Seismically Isolated Buildings during the Tokachi-oki Earthquake in 2003,” Journal menshin, JSSI No.45, pp. 34-37, Aug.2004.
  14. [14] A. Wada, et al., “Survey for Seismically Isolated Buildings in NiigataPrefecture,” Journal menshin, JSSI No.47, pp. 41-46, Feb.2005.
  15. [15] M. Tamari, et al., “Seismic Behavior of a Base-Isolated Buildingin Ojiya City at 2004 Chuetsu Earthquake,” Journal menshin, JSSINo.47, pp. 31-35, Feb. 2005.
  16. [16] Y. Yagawa, et al., “The Effect on Seismic Isolation of the InformationBuilding in Nagaoka City,” Journal menshin, JSSI No.48, pp.36-40, May 2005.
  17. [17] Y. Takenaka, et al., “Observation Record of the Isolated School Building during the Mid Niigata Prefecture Earthquake in 2004,”Journal menshin, JSSI No.48, pp. 56-59, May 2005.
  18. [18] M. Takayama, et al., “Reconnaissance Report on the Behavior ofthe Isolated Buildings during the earthquake of the West of fshore Fukuoka Prefecture in 2005,” Journal menshin, JSSI , No.48, pp.47-51, May 2005.
  19. [19] H. Morimoto, et al., “Quick Report on the Behavior of the Ohori Park Building during the Earthquake of the West offshore Fukuoka Prefecture in 2005,” Journal menshin, JSSI No.48, pp. 52-55, May2005.
  20. [20] N. Tanaka, “Conditions Report of the Seismically Isolated Buildings during the Noto Peninsula-Earthquake, 2007,” Journal menshin,JSSI No.56, pp. 33-37, May 2007.
  21. [21] M. Tamari, “Observed Records of a Base-Isolated Building in Ojiya City at 2007 Chuetsu Offshore Earthquake,” Journal menshin, JSSINo.58, pp. 23-25, Nov. 2007.
  22. [22] Y. Yagawa, et al., “The Effect on Seismic Isolation of the Information Building in Nagaoka City, 2nd Report,” Journal menshin, JSSINo.58, pp. 26-28, Nov 2007.
  23. [23] M. Mochizuki, “Reconnaissance Report of the Seismic Isolation Building in Kurihara City during the Iwate-Miyagi Inland Earthquake,”Journal menshin, JSSI No.62, pp. 35-38, Nov 2008.

*This site is desgined based on HTML5 and CSS3 for modern browsers, e.g. Chrome, Firefox, Safari, Edge, Opera.

Last updated on Apr. 22, 2024