Development of a High Precision Machining Center and its Motion Accuracy

Isao Oshita*, Hisashi Otsubo*, Masatoyo Sogabe**,
Yasusuke Iwashita**, and Yoshiaki Kakino***

*YASDA PRECISION TOOLS K.K., 1160 Hamanaka, Satosho-cho, Asakuchi, Okayama 719-0303, Japan

**FANUC LTD, 3580 Oshino-mura, Yamanashi 401-0597, Japan

***Kakino Research Laboratory, Iwakura-Hanazono-cho 256-5, Sakyo-ku, Kyoto 606-0024, Japan

Received:
February 20, 2009
Accepted:
April 10, 2009
Published:
July 5, 2009
Keywords:
high precision machining center, hydro-static guide way, linear motor, motion accuracy
Abstract
In the fabrication of parts and components using dies and molds for optical and/or medical use instruments, there are standing requirements that the accuracy of the form of the final products be maintained within a tolerance of 1.0 μm or less and that the roughness of the machined surface be held to 0.2 μm Ra or less while high production efficiency is maintained. The required accuracy of form, smoothness of the machined surface, and efficiency of production stated above can be achieved by high precision machine tools, but are beyond the performance properties expected of conventional, general-use machining centers, both of which are readily available on the open market. The authors (hereinafter collectively referred to as “the group”) who did this research agreed to refer to the machining centers that can satisfy both of the above-mentioned performance requirements as “Subject Machining Centers,” or “Subject MC,” while the other machining centers are referred to as “Conventional Machining Centers” or “Conventional MC.” This research includes a structural study of a Subject MC, followed by the actual designing and manufacturing processes of such a Subject MC, It was then subjected to an appraisal of its accuracy of motion from the data obtained through actual measurements, and a verification of the precision attained in the manufacturing process of the lens molds it produced. Through the combined use of a frictionless drive train using a hydrostatic guide and linear motor drive, together with the overall enhancement of the rigidity of the structure of the Subject MC, the following results were achieved.
1.Straight line motion accuracy with a deviation of 0.2 μm/100 mm or less was attained. Also, the roundness of 0.36 μm of the arc interpolation movement was achieved, confirmed with a grid encorder. (“Roundness” in this study is defined as the magnitude of the deviation of either an arc or a circle as measured against their geometrically correct counterparts.)
2.As a position loop gain as high as Kp = 140/s was attained with the servo mechanism adopted, it was confirmed that the actual use of the micro step feed at uniform separations of 10 nanometers had become possible.
3.It became possible to mold a lens with a roundness of 0.53 μm and a surface roughness of 0.05μm Ra after machining. (“Ra” denotes the arithmetical average of surface roughness after machining.)
Cite this article as:
I. Oshita, H. Otsubo, M. Sogabe, Y. Iwashita, and Y. Kakino, “Development of a High Precision Machining Center and its Motion Accuracy,” Int. J. Automation Technol., Vol.3 No.4, pp. 385-393, 2009.
Data files:
References
  1. [1] H. Suzuki, Y. Yamagata, and T. Higuchi, “Recent trend in Ultra-precision Machining System(<Special Issue>Latest Advances in Ultraprecision Machining Systems),” Journal of the Japan Society of Precision Engineering 72, 4, pp. 417-421, 2006.
  2. [2] M. Hamamura, J. Fujita, Y. Kakino, and A. Matsubara, “The Influence of Inertia Force and Viscous Friction on Contouring Errors in Circular Interpolation,” Journal of the Japan Society of Precision Engineering 69, 9, pp. 1306-1311, 2003.
  3. [3] R. Sato and M. Tsutsumi, “Mathematical Model of Feed Drive Systems Consisting of AC Servo Motor and Linear Ball Guide,” Journal of the Japan Society of Precision Engineering. Supplement. Contributed papers 71, 5, pp. 633-638, 2005.
  4. [4] S. Kasai, T. Tsukada, and S. Kato, NSK Technical Journal (649), pp. 27-36, 1988/08.
  5. [5] Y. Misawa, S. Sugita, and O. Satoru, SANYO DENKI Technical Report No.15, pp. 25-27, 2003.
  6. [6] “General Catalog,” of HEIDENHAIN 350 457-25.10/2004K pp. 44-45.

*This site is desgined based on HTML5 and CSS3 for modern browsers, e.g. Chrome, Firefox, Safari, Edge, Opera.

Last updated on Apr. 18, 2024