Tatsuyoshi Kajikawa, Eiji Takegami, Kohji Higuchi, Kazushi Nakano, and Satoshi Tomioka
Abstract: If the lines which connect the output terminal of a DC-DC converter and the load are long, the voltage actually crossing to the load will change greatly due to the impedances of the lines, producing drops in voltage. In this paper, a separate terminal apart from the output terminal of DC-DC converter senses the voltage across to the load, and it leads it to the load. As a result, the voltage across to the load is adjusted so that it does not experience large changes. This method is called remote sensing. When the lines become long, the usual method of adjusting the voltage across to the load cannot sufficiently suppress changes in it. In this paper, a robust digital controller to suppress the change in the voltage across the load is proposed. Experimental studies using DSP demonstrate that this type of digital controller successfully suppresses it.
Keywords: DC-DC power supply, digital control, robust control, remote sensing
Available Options: |